Common faults of cartoning machines
Common faults of cartoning machine one
The carton of the cartoner does not form or pops out at the mouth of the carton feeding template after being sucked down: 1. First check whether the carton is too hard. 2. Check whether the position of the guide rod for placing the carton and the box feeding template is not correct. 3. Check whether the small hook spring at the rear of the box feeding template is deformed. 4. Check whether the height of the suction head of the suction box and the box feeding track is correct.
Common faults of cartoning machine 2
The carton of the cartoning machine cannot be sucked down: 1. Check whether the carton is neatly placed. 2. Whether the carton is pasted together. 3. Whether the air pressure of the suction head is normal.
Common faults of cartoning machine three
The cartoning machine conveyor belt is stopped or stopped at the gap: 1. Check whether there is a shortage of materials when the cartoning machine is stopped at the gap, and automatically start the machine when it is added. 2. Stop the machine to check whether the power supply including the power supply part, the motor or the governor is normal.
Common faults of cartoning machine four
The cartoning machine manual can't be sucked down:
1. First check whether the instruction manual is deformed, causing the suction head to not suck.
2. Check whether the air of the suction head is parallel to the instruction manual.
3. Whether the width and size of the paper in the manual are different, the error must be within 1mm. The adjustment of the stacking position of the manual should be 0.5mm away from the inner edge when the suction head rises to the highest position.
4. The small hook above the suction head of the origami machine moves too early. Generally, the small hook should be inserted into the gap between the paper and the paper before the suction head is about to descend. The height of the small hook is adjusted by taking the air head to be at the highest position and 0.5mm away from it.